INFRA 0-1

INFRASTRUCTURE

Pitch bearing outer ring cracking

Monitored: Pitch bearing outer ring raceway · bolt holes · blade root connection

Problem

A crack at a bolt hole is invisible until it is too late

Cracks initiate at the bolt hole and propagate outward to the edge of the outer ring, across a raceway and bolt circle that cannot be inspected while the turbine is generating.

They are only detected by drone or visual inspection once they reach the surface, forcing immediate shutdown of the turbine.

Yearly inspections are time-consuming and generally not very effective, at $1,000-5,000 per turbine per year.

Left to grow, the crack leaves the bearing entirely: a $800k hub repair OR an expensive new blade, depending on the platform model.

Pitch bearing outer ring model
Flexible sensor probe installation on a wind turbine

Solution

Flexible sensor probes around the entire bearing ring

Continuous flexible probes around the bearing, between 10 and 20 depending on bearing diameter, covering the full outer bearing ring across all bolt holes.

Installation time 2 hours per bearing, no surface preparation, no paint removal, no drilling.

Sensor battery lifetime minimum 5 years, -40°C to +80°C, no return visits to service them.

Full service analysis of crack growth every month, week or day, depending on the expected crack growth rate and the availability of the replacement component.

Outcome

Cracks found under the surface, bearings ordered in time

Hub replacements no longer occur, and bearing ring replacements become scheduled jobs instead of emergency ones.

Detection of cracks before they reach the surface, through sub-surface magnetic field variations.

A crack detected when it is fully through means stopping operations immediately and absorbing the downtime. A crack detected as it starts to appear sub-surface means ordering and planning while the turbine stays in operation.

A · 000209

B · 000210

C · 000208